Not every landed house in Singapore follows the same rules. A bungalow, a semi-detached house and a terrace house each have their own plot sizes, setbacks and site coverage. Yet all of them share one height and bulk system called envelope control.
This guide explains landed house envelope control in Singapore. It then walks through each house type that the Urban Redevelopment Authority (URA) sets out in its Development Control (DC) handbooks. Your Qualified Person (QP) must still check your own plot, because URA may depart from its guidelines in a particular case.
What Is Landed House Envelope Control in Singapore?
From 11 May 2015, all landed housing follows URA’s envelope control guidelines. They define a three-dimensional limit for the house. The limit comes from two things: storey height and building setbacks.
URA states that the allowable gross floor area (GFA) of a landed house is the result of this height and envelope. Our guide on GFA vs built-up area explains how floor area is counted inside the envelope.
2-Storey and 3-Storey Areas
A landed house cannot exceed the 2-storey or 3-storey height control. It also cannot exceed any lower storey height shown in the designated landed housing plan in the Master Plan. URA’s clarifications on landed housing guidelines give the maximum building height:
- 12m in a 2-storey landed housing area; and
- 15.5m in a 3-storey landed housing area.
URA’s envelope diagrams show how that height is split. In a 2-storey area, up to 8.5m is below the attic zone, and the attic zone is up to 3.5m. In a 3-storey area, up to 12m is below the attic zone, with the same 3.5m on top.
To find your plot’s area, check the “Landed Housing Area” layer on URA SPACE. Sites outside designated areas and not guided by a street block plan are subject to a 3-storey control.
Where Height Is Measured From
Height is measured from the allowable external platform level. In low-lying areas, it is measured from the minimum platform level (MPL) set by PUB. On sloping sites, the front and rear levels are connected diagonally to form the envelope. Protrusions of up to 1m are allowed beyond it.
Other height limits can be stricter, such as aviation paths, conservation guidelines and urban design controls. A stricter technical height limit takes precedence.
Attics, Mezzanines and Roof Terraces
An attic is an incidental space allowed within the permitted envelope. Mezzanine floors no longer have to stay below 50% of a typical floor plate. URA assesses proposals with more than one mezzanine on their merits. URA made these flexibilities permanent in circular DC21-05 in July 2021.
A roof terrace on an attic roof must be at least 3m below the top of the permitted envelope. This keeps any future cover within the envelope. A roof less than 3m below the top must be an RC flat roof that is not accessible, except for maintenance.
What May Go Beyond the Envelope
Only minor items may go beyond the envelope: car porch roofs, roof eaves, ledges, screen walls between houses, safety railings and lift overruns. Specific limits include:
- lift overrun and safety barriers on RC flat roofs, up to 1m beyond the allowable height;
- dormer windows, up to 1m both vertically and horizontally, as clarified in URA circular DC25-05; and
- car porches, which URA’s bungalow and semi-detached handbooks say shall not exceed 4.5m in height.
If an existing house already exceeds the envelope, new additions and alterations (A&A) must not increase the building bulk further. URA assesses these cases on their merits.
Landed House Types and Their Key Controls
URA’s handbooks set separate rules for bungalows, semi-detached houses, terrace houses and strata landed housing. The figures below are net plot dimensions, which exclude land set aside for road or drainage reserves.
| House type | Minimum plot (net) | Site coverage (maximum) | Where URA allows it |
|---|---|---|---|
| Bungalow outside GCBA | 400 sqm; 10m wide | 50% overall; 40% sub-control | Any designated landed housing area |
| Good Class Bungalow (in a GCBA) | 1,400 sqm; 18.5m wide; 30m deep | 45% overall; 35% sub-control | 39 GCBAs; bungalows only |
| Semi-detached, side-to-side | 200 sqm; 8m wide | No site coverage section in the handbook | Semi-detached or mixed areas |
| Semi-detached, back-to-back | 200 sqm; 10m wide | No site coverage section in the handbook | Semi-detached or mixed areas |
| Terrace Type I | Intermediate 150 sqm, 6m wide; corner 200 sqm, 8m wide | No site coverage control | Mixed landed housing areas only |
| Terrace Type II | Intermediate 80 sqm, 6m wide; corner 80 sqm, 8m wide | No site coverage control | Mixed areas, in its own enclave |
| Strata landed housing | Each unit needs at least 50 sqm ground contact | 50% overall; 40% sub-control (45% and 35% in a GCBA) | Depends on the form; see below |
Setbacks are the second half of the envelope. Road buffers depend on road category: 24m for Category 1 and 12m for Category 2, both including a 5m green buffer. It is 7.5m for Category 3 and 4 roads, including a 3m green buffer, and 7.5m for Category 5 with none.
| House type | Main building from common boundary | Roof eaves from common boundary |
|---|---|---|
| Bungalow outside GCBA | 2m | 1m |
| Good Class Bungalow | 3m | 1.6m |
| Semi-detached | 2m | 1m |
| Terrace Type I and II | 2m | 1m |
If any plot abuts a Good Class Bungalow Area, URA applies the GCBA figures of 3m and 1.6m to that plot.
Bungalows (Detached Houses)
URA describes a bungalow as a detached landed house with its own land title. It can be built in any designated landed housing area if the plot meets the size, width and site coverage rules.
Two-Tier Site Coverage
Bungalows have a two-tier control. The overall site coverage counts every building feature raised 1m or more above ground. The sub-control counts the building up to its external facade, including balconies, planters, bay windows and roof terraces. It also counts 50% of the car porch roof area. Sun-shading features such as roof eaves are excluded from the sub-control.
URA circular DC24-05 introduced this sub-control for applications submitted on or after 1 March 2025. It also raised the overall limit for Good Class Bungalows from 40% to 45%.
Good Class Bungalows and GCBAs
URA lists 39 Good Class Bungalow Areas (GCBAs), including Nassim Road, Dalvey Estate, Holland Park and Belmont Park. In a GCBA, only bungalows are allowed. Conservation guidelines also apply in some, such as White House Park and Nassim Road, Chatsworth Park, and Holland Park and Ridout Park.
The GCBA plot rules are stricter. The minimum is 1,400 sqm, 18.5m wide and 30m deep. URA allows limited variations. One example is an infill bungalow on an existing plot that is already below 1,400 sqm. Another is a single residual plot after subdivision, if the shortfall comes from land vested for public purposes and is under 10%.
The envelope rules still follow the 2-storey or 3-storey height control for the area. A fully submerged basement in a GCBA must stay 2m from the boundary lines. Our basement guide covers this in more detail. GCBAs are also excluded from URA’s plan lodgment scheme.
Semi-Detached Houses
URA defines a semi-detached house as one half of a pair, each with its own title, sharing a party wall. The pair can be attached side-to-side or back-to-back.
If the neighbour rebuilds into a different form, such as a bungalow, the left-behind semi-detached house remains a semi-detached house as originally approved.
Height follows the same 12m or 15.5m envelope. The differences from a bungalow are the smaller plot, the 2m side setback and the shared wall.
Terrace Houses, Including Corner Terraces
A terrace house has its own title and forms part of a row of at least three houses abutting common party walls. URA allows terrace houses only in mixed landed housing areas.
Type I and Type II
URA recognises two terrace types, split by setback rules. Terrace Type I follows the standard road buffer. Terrace Type II has a 2m road setback for the building wall and 1m for roof eaves. It must sit in its own enclave.
Intermediate and Corner Units
The end house of a row is a corner terrace. Its minimum plot is larger: 200 sqm and 8m for Type I, against 150 sqm and 6m for an intermediate unit. URA states there is no site coverage control for either terrace type, so the envelope and setbacks do most of the work.
Linked Houses and Other Forms URA Mentions
The Planning (Development) Rules 2008 on Singapore Statutes Online list four landed dwelling-house types: detached, linked, semi-detached and terrace. URA’s Form DC 6 also refers to linked houses. In the handbook pages we opened, URA does not set out separate linked house or linked bungalow figures. Ask your QP which housing form and rules apply to your house.
URA’s handbooks also describe these forms:
- Rear garden landed housing, in designated enclaves and eight named estates, with a 3m front setback and a 7.5m rear setback.
- Houses guided by street block plans or conservation guidelines, where those rules also apply.
Strata Landed Housing
URA’s strata landed housing handbook covers strata bungalows, semi-detached and terrace houses on a shared site with communal facilities and one vehicular access point. Each unit must follow the envelope for its house type.
Strata landed housing has its own rules:
- at least 45% of the net site area must be communal open space, and at least 25% of the site area must be on-ground greenery;
- a strata bungalow can sit in bungalow areas, semi-detached areas or mixed areas, but strata terrace houses are limited to mixed areas;
- units must be at least 3m from the boundary with another development, and a 3-storey strata unit sharing a boundary with a GCBA needs 25m; and
- private enclosed spaces and private roof terraces in new strata landed projects submitted on or after 1 June 2023 count as GFA.
Changing From One House Form to Another
Redeveloping into a different form has strict conditions. For example, a terrace house can become a bungalow only if its plot is at least 400 sqm and 10m wide. The adjoining house must also still qualify as a corner terrace of at least 200 sqm and 8m. Outside designated landed housing areas, the left-behind plot must be at least 1,000 sqm.
Detaching from a neighbour leaves an exposed party wall. The owner must give BCA an engineer’s certification of the remaining house. The exposed wall must be plastered and painted, and the neighbour must have access for repairs.
What This Means for Your Renovation or Rebuild
For A&A, URA’s tests include added GFA of no more than 50% of the approved GFA. An extra storey or a change in housing form is treated as reconstruction. Our guide to landed house renovation approval explains these tests and the 1 April 2025 plan lodgment changes. Our house reconstruction guide covers the wider rebuild process.
Buying an older house? A taller neighbour does not prove what you can build. Our guide to buying a landed house to rebuild shows how to test the plot first.
Questions to Ask Your QP
- Is my plot in a 2-storey or 3-storey area, and is any other height limit stricter?
- Which housing form is on my approved plans, and what are my plot’s net size and width?
- Can my attic, mezzanine or roof terrace fit inside the envelope?
- Does my existing house already exceed the envelope?
Frequently Asked Questions
How tall can a landed house be in Singapore?
URA states the maximum building height is 12m in a 2-storey landed housing area and 15.5m in a 3-storey area. Height is measured from the allowable external platform level. Check your plot’s area on URA SPACE.
What is the minimum plot size for a bungalow?
Outside a Good Class Bungalow Area, URA requires 400 sqm and a 10m width. Within a GCBA, it requires 1,400 sqm, an 18.5m width and a 30m depth. These are net figures after land for road or drainage reserves.
Does a terrace house have a site coverage limit?
URA’s terrace house handbook says there is no site coverage control for Terrace Type I or Type II. Envelope control and setbacks still apply.
Can I add an attic or roof terrace?
URA allows an attic within the permitted envelope. A roof terrace on an attic roof must be at least 3m below the top of the envelope. Otherwise the roof must be a non-accessible RC flat roof.
Can a terrace house be rebuilt as a bungalow?
Only under URA’s conditions. The plot must be at least 400 sqm and 10m wide, and the adjoining house must still qualify as a corner terrace. A change in housing form is treated as reconstruction.
Plan Your Landed House With a Builder Who Reads the Envelope
At Three E Building Construction, we build landed home rebuilds, extensions and A&A works. We work with your architect and engineers so the design and site work line up. If you are planning a landed house, talk to 3E Build about your project before you finalise the design. Builder with Integrity.
Sources (the URA and Singapore Statutes Online pages linked above) checked on 12 November 2026 (Singapore time). General guidance only, not professional advice. Your QP or architect must assess your specific plot.