Homeowners often ask whether there is a plot ratio landed house Singapore rule, the way a flat or condominium is capped by a Master Plan Gross Plot Ratio (GPR). For a typical land-titled house in a designated landed housing area, the Urban Redevelopment Authority (URA) does not set the house size with a fixed plot ratio.
URA instead uses envelope control. The allowable gross floor area (GFA) is the result of the permitted building height and the envelope formed by storey-height limits and setbacks. This guide covers the plot-size and site-coverage rules that still apply, and when a Master Plan plot ratio comes into play.
Your Qualified Person (QP) must still check your own plot. URA may depart from its general guidelines in a particular case, and a street block plan can be stricter.
What Plot Ratio Means, and Why Landed Houses Are Different
URA’s Gross Floor Area handbook defines Gross Plot Ratio as the ratio of a building’s GFA to its site or plot area. For flats and condominiums, development potential is guided by the GPR shown in the Master Plan. That figure is an upper bound, and site constraints can mean you cannot use all of it.
Landed houses work differently. In its handbooks for bungalows, semi-detached houses and terrace houses, URA states that the allowable GFA for landed housing is the result of the allowable building height and envelope. Our guide to GFA vs built-up area explains how floor area is counted inside that envelope.
If you divide a neighbour’s approved GFA by their land area, the number may look like a plot ratio. It is a result, not a right you can copy onto your own plot.
What Actually Controls the Size of a Landed House
Envelope control and storey height
From 11 May 2015, all landed housing follows URA’s envelope control guidelines. They set a three-dimensional limit based on storey height and building setbacks. The house must stay inside that envelope.
URA’s clarifications on landed housing guidelines give the maximum building height:
- 12m in a 2-storey landed housing area; and
- 15.5m in a 3-storey landed housing area.
The house also cannot exceed a lower storey height shown in the Master Plan’s designated landed housing plan. A stricter technical height, such as an aviation path or conservation guideline, takes precedence. Height is measured from the allowable external platform level. In low-lying areas, it is measured from the minimum platform level (MPL) set by PUB.
To find your plot’s area, check the “Landed Housing Area” layer on URA SPACE. Sites outside designated landed housing areas, and not guided by a street block plan, are subject to a 3-storey height control. Our guide to landed house envelope control in Singapore walks through the envelope and each housing form.
Setbacks and the shape of the envelope
The sides of the envelope come from road buffers and common-boundary setbacks. On Category 3 to 5 roads, the usual front setback for the main building is 7.5m for bungalows, semi-detached houses and Terrace Type I houses. Terrace Type II houses have a fixed 2m front setback and must sit in their own enclave. Category 1 and 2 roads have deeper road buffers.
Side and rear setbacks for the main building are generally 2m, or 3m for a Good Class Bungalow. If a plot abuts a Good Class Bungalow Area, URA applies the GCBA figures of 3m and 1.6m for roof eaves to that plot.
Plot Size, Width and Site Coverage by House Type
URA measures plot size and width as net figures. They exclude land that must be vested to the State, such as a drainage reserve or road reserve.
| Housing type | Minimum plot size (net) | Minimum width (net) | Site coverage |
|---|---|---|---|
| Good Class Bungalow (within a GCBA) | 1,400 sqm, and 30m minimum depth | 18.5m | Sub-control 35%; overall 45% |
| Bungalow (outside a GCBA) | 400 sqm | 10m | Sub-control 40%; overall 50% |
| Semi-detached, side-to-side, including corner terrace Type I | 200 sqm | 8m | No site coverage control |
| Semi-detached, back-to-back | 200 sqm | 10m | No site coverage control |
| Terrace Type I, intermediate | 150 sqm | 6m | No site coverage control |
| Terrace Type I, corner | 200 sqm | 8m | No site coverage control |
| Terrace Type II, intermediate | 80 sqm | 6m | No site coverage control |
| Terrace Type II, corner | 80 sqm | 8m | No site coverage control |
URA circular DC24-05 introduced the two-tier site coverage control for bungalows, for development applications submitted on or after 1 March 2025. It also raised the overall limit for Good Class Bungalows from 40% to 45%.
The overall control counts every building feature raised 1m or more above ground. The sub-control is measured to the external facade, including balconies, planters, bay windows and roof terraces, plus 50% of the car porch roof area. Sun-shading features such as roof eaves are excluded from the sub-control.
The terrace handbook states that there is no site coverage control for Terrace Type I or Type II. URA’s prevailing planning controls page also lists “No control” for semi-detached and terrace houses. Envelope control and setbacks still limit the footprint.
URA lists 39 Good Class Bungalow Areas. In a GCBA, or in other bungalow areas, only bungalows are allowed. Semi-detached houses may be built in semi-detached or mixed landed areas, and terrace houses in mixed landed areas. A street block plan, if any, takes precedence over the table.
Attics, Mezzanines and Basements
An attic, a mezzanine or a basement can add usable space, but they do not create a separate plot-ratio budget.
An attic is an incidental space within the permitted 2-storey or 3-storey envelope. Mezzanine floors no longer have to stay below 50% of a typical floor plate. URA assesses proposals with more than one mezzanine on their merits. A roof terrace on an attic roof must sit at least 3m below the top of the envelope. A roof closer than that must be a non-accessible RC flat roof, except for maintenance.
Basements are allowed within setback limits. A fully submerged basement outside a GCBA may, subject to technical requirements and no adverse impact on the neighbour, go up to the lot boundary if the wall has no openings into the adjoining site.
Within a GCBA, it must stay 2m from the boundary lines. A basement with protrusion follows the road buffer and the usual building setbacks. See our guide to building a basement for a landed house.
URA’s handbook says covered enclosed spaces are included as GFA regardless of accessibility, use or height, so an enclosed attic or basement room is generally counted. The car parking space within a car porch or garage of non-strata landed housing is excluded from GFA. Private car parking lots that form part of a strata-titled unit do not get that exclusion.
When a Plot Ratio Does Apply
Strata landed housing
Strata landed housing is different from a land-titled house. The units share one development site, communal facilities and a single vehicular access. Each unit’s footprint must have at least 50 sqm of ground contact, and its GFA is still the result of its building form and envelope.
For a development of strata landed housing only, URA says the overall GFA is the result of the number of units allowed, capped by a formula based on typical footprint and location:
- Within a GCBA: 35% of the site area divided by 500 sqm, the typical Good Class Bungalow footprint, rounded down; and
- Outside a GCBA, for a single housing form: 40% of the site area divided by 200 sqm for bungalows, or by 100 sqm for terrace or semi-detached housing, rounded down.
URA may impose a stricter unit cap in localised areas of concern. A mixed-form development outside a GCBA must keep the combined typical footprints within 40% of the site area. Strata landed developments also have the same two-tier site coverage limits as bungalows, and must set aside at least 45% of the nett site area as communal open space, including at least 25% of the site area as communal on-ground greenery.
A Master Plan Gross Plot Ratio does control overall GFA when the development mixes strata landed housing with flat units. The actual ratio is the figure on that site’s Master Plan, not a single island-wide number. Such hybrid developments are not accorded condominium status, and they are not allowed in designated landed housing areas.
Landed houses on other residential land
A bungalow may also be built on land zoned for residential use if the site meets the minimum plot size, plot width and site coverage requirements. URA may consider landed housing on other residential-zoned sites depending on site context. If the site is outside a designated landed housing area and is not guided by a street block plan, it is subject to a 3-storey height control, and the prevailing landed housing guidelines still apply.
Check the Master Plan zoning and any plot ratio shown for the site on URA SPACE, and ask your QP whether any intensity control applies in addition to the envelope.
Street block plans and conservation
Where a street block plan guides landed housing, the guidelines in that plan apply. Conservation guidelines also apply to gazetted landed houses, including historic districts such as Blair Plain, Cairnhill and Emerald Hill.
Why GFA Still Matters Even Without a Fixed Plot Ratio
Even when a plot ratio is not the cap on house size, GFA is still computed and still has consequences.
First, URA still needs a GFA figure for planning assessment. To qualify as an additions and alterations (A&A) application, the added GFA must not exceed 50% of the existing and approved GFA, among other tests in URA’s Form DC 6 notes. An extra storey or a change in housing form is treated as reconstruction. See our guide to landed house renovation approval.
Second, from 1 August 2022, the Land Betterment Charge (LBC) replaced Differential Premium, Development Charge and Temporary Development Levy. The Singapore Land Authority (SLA) collects it. LBC is a tax on the increase in land value arising from a chargeable consent, such as planning permission.
It is computed from the difference between the post-chargeable and pre-chargeable valuations. The post-chargeable figure is based on the proposed use and intensity, which URA’s circular describes as gross floor area. Historical Master Plans 1958, 1980 and 2003 may still affect the pre-chargeable valuation. Ask your QP whether any LBC applies to your proposal.
None of this turns GFA into a plot-ratio cap for a typical landed house. Our GFA vs built-up area guide explains what URA counts. Our house reconstruction guide covers the wider rebuild process.
How to Check the Rules for Your Own Plot
- On URA SPACE, open the Master Plan zoning and the “Landed Housing Area” layer under Control Plans.
- Check whether the plot is in a 2-storey or 3-storey area, a Good Class Bungalow Area, or a street block or conservation area.
- Confirm the approved housing form, and the net plot size and width after any road or drainage reserve.
- Ask your QP how the envelope, setbacks and bungalow site coverage apply. If you are buying to rebuild, our guide to buying a landed house to rebuild sets out what to check first.
Frequently Asked Questions
Is there a plot ratio for landed houses in Singapore?
For a typical land-titled house in a designated landed housing area, no. URA does not set the house size with a fixed plot ratio. The allowable GFA is the result of the permitted height and envelope. A Master Plan GPR does apply when a development mixes strata landed housing with flats.
How is the size of a landed house controlled if there is no plot ratio?
Envelope control sets a three-dimensional limit from storey height and setbacks. The maximum height is 12m in a 2-storey area and 15.5m in a 3-storey area. Plot size, width and, for bungalows, two-tier site coverage also apply.
What is the site coverage for a Good Class Bungalow?
For applications submitted on or after 1 March 2025, URA’s two-tier control is a 35% sub-control and a 45% overall limit within a Good Class Bungalow Area. Outside a GCBA, a bungalow is limited to 40% and 50%. Semi-detached and terrace houses have no site coverage control, but envelope and setback rules still apply.
Do attics and basements count towards GFA?
Generally yes, if they are covered enclosed spaces. URA includes those spaces as GFA regardless of accessibility, use or height. The car parking space within a car porch or garage of non-strata landed housing is excluded. An attic must also fit within the permitted envelope.
Does plot ratio apply to strata landed housing?
For strata landed units only, overall GFA is the result of the number of units allowed under URA’s unit-cap formulae, and each unit’s GFA is the result of its form and envelope. If the development mixes strata landed housing with flats, overall GFA is controlled by the site’s Master Plan Gross Plot Ratio.
Why does GFA still matter if there is no plot ratio cap?
URA still computes GFA for planning assessment, including the 50% GFA test that helps distinguish A&A from reconstruction. From 1 August 2022, the Land Betterment Charge, which replaced Development Charge, is also assessed from the proposed use and intensity, described as gross floor area, in the planning permission.
Plan Your Rebuild Around the Envelope, Not a Copied Plot Ratio
At Three E Building Construction, we build landed home rebuilds, extensions and A&A works. We work with your architect and engineers so the design and site work line up with URA’s envelope and GFA rules. If you are planning a landed house, talk to 3E Build. Builder with Integrity.
Sources (the URA and SLA pages linked above) checked on 16 November 2026 (Singapore time). General guidance only, not professional advice. Your QP or architect must assess your specific plot.
